Improved precision in CHARMED assessment of white matter through sampling scheme optimization and model parsimony testing

Journal article


De Santis, Silvia, Assaf, Y., Evans, C J. and Jones, D. K.. (2014). Improved precision in CHARMED assessment of white matter through sampling scheme optimization and model parsimony testing. Magnetic Resonance in Medicine. 71(2), pp. 661 - 671. https://doi.org/10.1002/mrm.24717
AuthorsDe Santis, Silvia, Assaf, Y., Evans, C J. and Jones, D. K.
Abstract

Purpose: The composite hindered and restricted model of diffusion provides microstructural indices that are potentially more specific than those from diffusion tensor imaging. However, in comparison to diffusion tensor imaging, the acquisition time is longer, limiting clinical applications. Moreover, the model requires several parameters to be estimated whose confidence intervals can be large. Here, the composite hindered and restricted model of diffusion acquisition and data processing pipelines are optimized to extend the utility of this approach. Methods: A multishell sampling scheme was optimized using the electrostatic repulsion algorithm, combined with optimal ordering. The optimal protocol, using as few measurements as possible, was determined through leave-n-out analyses. Parsimonious model selection criteria were used to select between nested models, comprising up to three restricted compartments. The schemes were evaluated using both through Monte-Carlo simulations and in vivo data. Results: The optimization/model selection procedure resulted in increased accuracy and precision on the estimated parameters, allowing for a reduction in acquisition time and marked improvements in data quality. The final protocol provided whole brain coverage data in only 12 min. Conclusion: Through careful optimization of the acquisition and analysis pipeline for the composite hindered and restricted model of diffusion, it is possible to reduce acquisition time for whole brain datasets to a time that is clinically applicable. Magn Reson Med 71:661–671, 2014. VC 2013 Wiley Periodicals, Inc.

KeywordsCHARMED; model parsimony; Bayesian information criterion; optimized gradient scheme; diffusion MRI
Year2014
JournalMagnetic Resonance in Medicine
Journal citation71 (2), pp. 661 - 671
PublisherJohn Wiley & Sons, Inc.
ISSN0740-3194
Digital Object Identifier (DOI)https://doi.org/10.1002/mrm.24717
Scopus EID2-s2.0-84892439114
Page range661 - 671
Publisher's version
File Access Level
Controlled
Place of publicationUnited States
Permalink -

https://acuresearchbank.acu.edu.au/item/87x56/improved-precision-in-charmed-assessment-of-white-matter-through-sampling-scheme-optimization-and-model-parsimony-testing

Restricted files

Publisher's version

  • 47
    total views
  • 0
    total downloads
  • 0
    views this month
  • 0
    downloads this month
These values are for the period from 19th October 2020, when this repository was created.

Export as